Tsamba la mbendera

1 × 8 1 * 8 1: 8 Mini chubu mtundu PLC CHIKWANGWANI chamawonedwe ziboda

Kufotokozera Kwachidule:

• Kutayika kochepa kolowetsa, kutayika kwakukulu kobwerera

• Wabwino Kutentha bata

• Kubwereza kwabwino ndi kusinthanitsa

• Kupirira kwabwino kwamakina

• Kuchiza nthawi ndi kuwongolera kutentha

• Miyezo yolimba yoyesera ndi njira zaubwino

• Kuteteza chilengedwe (ROHS Compliance)

• Chingwe cha fiber kuwala patch chikhoza kusinthidwa malinga ndi zomwe makasitomala amafuna (Cholumikizira Chokhazikika / Utali / phukusi…)


Tsatanetsatane wa Zamalonda

Zolemba Zamalonda

Mafotokozedwe Akatundu:

PLC fiber optic splitter imachokera ku teknoloji ya planar Lightwave circuit ndi ndondomeko yogwirizanitsa bwino, imatha kugawanitsa imodzi / yapawiri yamagetsi opangidwa ndi kuwala kosiyanasiyana ndipo imatchulidwa 1 * N kapena 2 * N.

PLC fiber optic splitter ndi mtundu wa chipangizo chowongolera magetsi chomwe chimapangidwa pogwiritsa ntchito ukadaulo wa silica optical waveguide.

Imakhala ndi kukula pang'ono, kudalirika kwakukulu, kutalika kwa mawonekedwe ogwiritsira ntchito komanso kufananiza kwanjira, ndipo imagwiritsidwa ntchito kwambiri pamanetiweki a PON kuti azindikire kugawanika kwamphamvu kwamagetsi.

PLC fiber optic splitter imapereka magwiridwe antchito apamwamba, kukhazikika kwambiri komanso kudalirika kwakukulu, kumakwaniritsa zofunikira zosiyanasiyana zogwiritsira ntchito m'malo osiyanasiyana.

1x8 PLC fiber optic splitter yabwera ndi zolowetsa 1 ndi zotulutsa 8. Kulowetsa ndi kutulutsa chingwe kutalika kungakhale 0.6m, 1.0m, 1.5m kapena makonda. Imapezeka ndi zolumikizira zamitundu yambiri monga: SC/UPC, SC/APC, LC/UPC, LC/APC,

1x8 PLC CHIKWANGWANI chamawonedwe ziboda zambiri ntchito 8 madoko pachiyika phiri bokosi kwa chimango distriution, kapenanso lonse ntchito 8 madoko kunja CHIKWANGWANI chamawonedwe yogawa bokosi.

Ntchito:

Zithunzi za FTTX

Zithunzi za PON

Zogwirizana ndi CATV

Kuyankhulana kwa Data

Telecommunication

Kugawidwa kwa Chizindikiro cha Optical

Mbali:

Kutayika koyikapo pang'ono, kutayika kwakukulu kobwerera

Wabwino Kutentha bata

Kubwereza kwabwino komanso kusinthanitsa

Wabwino makina kupirira

Nthawi yochiritsa bwino komanso kuwongolera kutentha

Miyezo yolimba yoyesera ndi njira zaubwino

Chitetezo cha chilengedwe (ROHS Compliance)

Chingwe cha fiber kuwala patch chikhoza kusinthidwa malinga ndi zomwe makasitomala amafuna (Cholumikizira Chokhazikika / Utali / phukusi ...)

Parameter:

Kukonzekera kwa Port 1*8
Kutayika Kwambiri (dB) Max 10.6
Kutayika Kufanana (dB) 1.0
PDL(dB) 0.25
Wavelength Dependent Loss(dB) 0.3
Temp. Kutayika Kodalira (-40~85 ) (dB) 0.4

Zindikirani: Zomwe zili pamwambapa ndi za splitter popanda cholumikizira.

Kukonzekera kwa Port 1*8
Kutayika Kwambiri (dB) Max 10.8
Kutayika Kufanana (dB) 1.0
PDL(dB) 0.2
Wavelength Dependent Loss (dB) 0.3
Temp. Kutayika Kodalira (-40~85°C ) (dB) 0.4

Zindikirani: Zomwe zili pamwambapa ndi za splitter yokhala ndi cholumikizira.

Mtheradi Maximum Mavoti

Parameter

Chizindikiro

Min.

Chitsanzo

Max.

Chigawo

Kutentha Kosungirako

TS

-40

 

+ 85

°C

Kutentha kwa Ntchito SFP+ -10G-LR

TA

0

 

70

°C

SFP+ -10G-LR-I

-40

 

+ 85

°C

Maximum Supply Voltage

Vcc

-0.5

 

4

V

Chinyezi Chachibale

RH

0

 

85

%

Makhalidwe Amagetsi (TOP = 0 mpaka 70 °C, VCC = 3.135 mpaka 3.465 Volts)

Parameter

Chizindikiro

Min.

Chitsanzo

Max.

Chigawo

Zindikirani

Supply Voltage

Vcc

3.135

 

3.465

V

 

Supply Current

Icc

 

 

430

mA

 

Kugwiritsa Ntchito Mphamvu

P

 

 

1.5

W

 

Gawo la Transmitter:
Lowetsani kusiyana kwa impedance

Rin

 

100

 

Ω

1

Tx Input Single Ended DC Voltage Tolerance (Ref VeeT)

V

-0.3

 

4

V

 

Kusintha kwamphamvu kwamagetsi osiyanasiyana

Vin, pp

180

 

700

mV

2

Kutumiza Disable Voltage

VD

2

 

Vcc

V

3

Kutumiza Yambitsani Voltage

VEN

Vee

 

Mtengo +0.8

V

 

Gawo la Wolandira:
Kulekerera kwa Voltage Kumodzi Komaliza

V

-0.3

 

4

V

 

Mphamvu ya Rx Output Diff Voltage

Vo

300

 

850

mV

 

Rx Output Rise and Fall Time

Tr/Tf

30

 

 

ps

4

Zolakwa za LOS

VLOS cholakwika

2

 

VccHOST

V

5

LOS Normal

VLOS chizolowezi

Vee

 

Mtengo +0.8

V

5

Ndemanga:1. Zolumikizidwa mwachindunji ndi zikhomo za data za TX. Kulumikizana kwa AC kuchokera ku mapini kupita ku IC driver driver.
2. Pa SFF-8431 Rev 3.0.
3. Mu 100 ohms kusiyana kuthetsedwa.
4. 20% ~80%.
5. LOS ndizotulutsa zotseguka zosonkhanitsa. Iyenera kukokedwa ndi 4.7k - 10kΩ pa bolodi lokhala nawo. Kugwira ntchito mwachizolowezi ndi logic 0; kutayika kwa chizindikiro ndi logic 1. Kuchuluka kwamagetsi kukoka ndi 5.5V.

Optical Parameters (TOP = 0 mpaka 70 ° C, VCC = 3.135 mpaka 3.465 Volts)

Parameter

Chizindikiro

Min.

Chitsanzo

Max.

Chigawo

Zindikirani

Gawo la Transmitter:
Center Wavelength

λt

1290

1310

1330

nm

 

spectral wide

λ

 

 

1

nm

 

Avereji Mphamvu ya Optical

Pavg

-6

 

0

dBm

1

Mphamvu ya Optical OMA

Poma

-5.2

 

 

dBm

 

Laser Off Power

Poff

 

 

-30

dBm

 

Chiwerengero cha Kutha

ER

3.5

 

 

dB

 

Chilango Chobalalitsa cha Transmitter

TDP

 

 

3.2

dB

2

Relative Intensity Noise

Rin

 

 

-128

dB/Hz

3

Optical Return Loss Tolerance

 

20

 

 

dB

 

Gawo la Wolandira:
Center Wavelength

λr

1260

 

1355

nm

 

Kumverera kwa Receiver

Sen

 

 

-14.5

dBm

4

Kukhudzidwa Kwambiri (OMA)

SenST

 

 

-10.3

dBm

4

Los Assert

LOSA

-25

 

-

dBm

 

Los Dessert

LOSD

 

 

-15

dBm

 

Matenda a Hysteresis

LOSH

0.5

 

 

dB

 

Zochulukira

Loweruka

0

 

 

dBm

5

Receiver Reflectance

Rrx

 

 

-12

dB

 

Ndemanga:1. Avereji ya ziwerengero zamphamvu ndizodziwitsa kokha, pa IEEE802.3ae.
2. Chithunzi cha TWDP chimafuna kuti gulu la alendo likhale logwirizana ndi SFF-8431. TWDP imawerengedwa pogwiritsa ntchito kachidindo ka Matlab koperekedwa mu ndime 68.6.6.2 ya IEEE802.3ae.
3. 12dB chiwonetsero.
4. Mikhalidwe ya mayeso olandila opsinjika pa IEEE802.3ae. Kuyesa kwa CSRS kumafuna gulu lokhalamo kuti likhale logwirizana ndi SFF-8431.
5. Receiver overload yotchulidwa mu OMA ndi pansi pa chikhalidwe choipitsitsa kwambiri.

Makhalidwe a Nthawi

Parameter

Chizindikiro

Min.

Chitsanzo

Max.

Chigawo

TX_Disable Assert Time

t_kuchoka

 

 

10

us

TX_Disable Negate Time

t_pa

 

 

1

ms

Nthawi Yoyambitsa Phatikizaninso Kukonzanso kwa TX_FAULT

t_ine

 

 

300

ms

TX_FAULT kuchokera ku Fault kupita ku Assertion

t_fault

 

 

100

us

TX_Disable Time Kuti Muyambe Kukonzanso

t_kusintha

10

 

 

us

Wolandira Kutayika kwa Nthawi Yotsimikizira Ma Signal

TA,RX_LOS

 

 

100

us

Wolandira Kutayika kwa Signal Deassert Time

Td,RX_LOS

 

 

100

us

Rate-Sankhani Chage Time

t_ratesel

 

 

10

us

Seri ID Clock Time

t_serial-clock

 

 

100

kHz

Pin Ntchito

Chithunzi cha Host Board Connector Block Pin Nambala ndi Dzina

mankhwala3

Pin Ntchito Matanthauzo

PIN

Dzina

Ntchito

Zolemba

1

VeeT Module transmitter ground

1

2

Tx Zolakwika Kulakwitsa kwa transmitter ya module

2

3

Tx Letsani Kuletsa Transmitter; Izimitsa kutulutsa kwa laser transmitter

3

4

SDL 2 serial interface data input/output (SDA)

 

5

Mtengo wa magawo SCL 2 serial interface clock input (SCL)

 

6

MOD-ABS Module Kulibe, kulumikizana ndi VeeR kapena VeeT mu gawoli

2

7

RS0 Mulingo kusankha0, mwasankha kuwongolera SFP + wolandila. Pamene mkulu, lolowera deta mlingo>4.5Gb/s; ikakhala yotsika, kuchuluka kwa data yolowetsa <= 4.5Gb/s

 

8

LOS Wolandila Kutayika kwa Chizindikiro cha Chizindikiro

4

9

RS1 Mulingo kusankha0, mwasankha kuwongolera SFP + transmitter. Pamene mkulu, lolowera deta mlingo> 4.5Gb/s; ikakhala yotsika, kuchuluka kwa data yolowetsa <= 4.5Gb/s

 

10

VeeR Malo olandila module

1

11

VeeR Malo olandila module

1

12

RD- Receiver inverted data kunja

 

13

RD+ Receiver sanali inverted data kunja

 

14

VeeR Malo olandila module

1

15

VccR Wolandila module 3.3V

 

16

VccT Module transmitter 3.3V

 

17

VeeT Module transmitter ground

1

18

TD+ Transmitter inverted data yatulutsidwa

 

19

TD- Ma Transmitter osatembenuzidwa atulutsidwa

 

20

VeeT Module transmitter ground

1

Zindikirani:1. Zikhomo zapansi za module zidzasiyanitsidwa ndi vuto la module.
2. Pini iyi ndi pini yotsegulira yosonkhanitsa / kukhetsa ndipo idzakokedwa ndi 4.7K-10Kohms kupita ku Host_Vcc pa bolodi yolandira.
3. Pini iyi idzakokedwa ndi 4.7K-10Kohms kupita ku VccT mu gawoli.
4. Pini iyi ndi pini yotsegulira yosonkhanitsa / kukhetsa ndipo idzakokedwa ndi 4.7K-10Kohms kupita ku Host_Vcc pa bolodi yolandira.

SFP Module EEPROM Information ndi Management

Ma module a SFP amagwiritsa ntchito 2-waya serial communication protocol monga tafotokozera mu SFP -8472. Zambiri za ID za ma module a SFP ndi magawo a Digital Diagnostic Monitor atha kupezeka kudzera mu I.2C mawonekedwe adilesi A0h ndi A2h. Memory imapangidwa mu Table 1. Zambiri za ID (A0h) zalembedwa mu Table 2.,ndi tmafotokozedwe a DDM pa adilesi A2h. Kuti mumve zambiri zamapu okumbukira komanso matanthauzidwe a byte, chonde onani SFF-8472, "Digital Diagnostic Monitoring Interface for Optical Transceivers". Magawo a DDM adasinthidwa mkati.

Table1. Digital Diagnostic Memory Map (Mafotokozedwe Apadera a Data Field).

mankhwala1

Table 2- EEPROM Serial ID Memory Zamkatimu (A0h)

Deta Adilesi

Utali

(Byte)

Dzina la

Utali

Kufotokozera ndi Zamkatimu

Minda ya ID Yoyambira

0

1

Chizindikiritso

Mtundu wa seri transceiver (03h=SFP)

1

1

Zosungidwa

Chizindikiritso chowonjezera chamtundu wa serial transceiver (04h)

2

1

Cholumikizira

Khodi ya cholumikizira cholumikizira (07=LC)

3-10

8

Transceiver

10G Base-LR

11

1

Encoding

64B/66B

12

1

BR, Dzina

Mulingo wodziwika bwino wa baud, gawo la 100Mbps

13-14

2

Zosungidwa

(0000h)

15

1

Utali (9um)

Kutalika kwa ulalo kumathandizidwa ndi 9/125um fiber, mayunitsi a 100m

16

1

Utali (50um)

Kutalika kwa ulalo kumathandizidwa ndi 50/125um fiber, mayunitsi a 10m

17

1

Utali (62.5um)

Kutalika kwa ulalo kumathandizidwa ndi 62.5 / 125um fiber, mayunitsi a 10m

18

1

Utali (Mkuwa)

Kutalika kwa ulalo kumathandizidwa ndi mkuwa, mayunitsi a mita

19

1

Zosungidwa

 

20-35

16

Dzina la ogulitsa

Dzina la ogulitsa SFP:VIP Fiber

36

1

Zosungidwa

 

37-39

3

Wogulitsa OUI

SFP transceiver wogulitsa OUI ID

40-55

16

Wogulitsa PN

Nambala ya Gawo: “SFP+ -10G-LR” (ASCII)

56-59

4

Vendor rev

Mulingo wobwereza wa gawo la nambala

60-62

3

Zosungidwa

 

63

1

CCID

Zocheperako pang'ono za kuchuluka kwa data mu adilesi 0-62
Minda ya ID Yowonjezera

64-65

2

Njira

Imawonetsa ma signature a SFP omwe amatsatiridwa

(001Ah = LOS, TX_FAULT, TX_DISABLE zonse zothandizidwa)

66

1

BR, max

Mlingo wapamwamba kwambiri, mayunitsi a%

67

1

BR, min

Mphepete ya mtengo wotsika, mayunitsi a%

68-83

16

Wogulitsa SN

Nambala ya seri (ASCII)

84-91

8

Date kodi

VIP Fiber's Manufacturing date kodi

92-94

3

Zosungidwa

 

95

1

CCEX

Chongani khodi ya ID Fields yowonjezera (maadiresi 64 mpaka 94)
Minda Ya ID Yotsimikizika Yogulitsa

96-127

32

Zowerengeka

VIP Fibertsiku lenileni, kuwerenga kokha

128-255

128

Zosungidwa

Zasungidwa ku SFF-8079

Makhalidwe a Digital Diagnostic Monitor

Deta Adilesi

Parameter

Kulondola

Chigawo

96-97 Transceiver Internal Kutentha ±3.0 °C
100-101 Laser Bias Current ±10 %
100-101 Tx Output Power ±3.0 dBm
100-101 Mphamvu Yolowetsa Rx ±3.0 dBm
100-101 VCC3 Internal Supply Voltage ±3.0 %

Kutsata Malamulo

TheSFP+ -10G-LR imagwirizana ndi International Electromagnetic Compatibility (EMC) komanso zofunikira ndi miyezo yapadziko lonse lapansi yachitetezo (onani zambiri mu Gulu lotsatira).

Electrostatic Discharge

(ESD) kupita ku Zikhomo Zamagetsi

MIL-STD-883E

Njira 3015.7

Kalasi 1(>1000 V)
Electrostatic Discharge (ESD)

ku Duplex LC Receptacle

IEC 61000-4-2

GR-1089-CORE

Yogwirizana ndi miyezo
Mphamvu yamagetsi

Kusokoneza (EMI)

FCC Gawo 15 Gulu B

EN55022 Gawo B (CISPR 22B)

Gulu la VCC B

Yogwirizana ndi miyezo
Chitetezo cha Maso a Laser FDA 21CFR 1040.10 ndi 1040.11

EN60950, EN (IEC) 60825-1,2

Yogwirizana ndi Class 1 laser

mankhwala.

Alangizidwa Circuit

mankhwala4

Analimbikitsa Host Board Power Supply Circuit

mankhwala5

Yolangizidwa Yoyenda Yothamanga Kwambiri

Zaukadaulo:

Kutalika kwa fiber 1.0mkapena Makonda
Mtundu Wolumikizira SC,LC,

FC

kapena Makonda

Mtundu wa Optical Fiber G652DG657A1

kapena Makonda

Kuwongolera (dB) Min * 55
Bwererani Kutaya (dB) Min * 55 (50)
Kugwiritsa Ntchito Mphamvu (mW) 300
Kutalika kwa ntchito (nm) 1260 ~ 1650
Kutentha kwantchito(°C) -40 ~ +85
Kutentha Kosungirako(°C) -40 ~ +85

Mzere wopanga:

product_1

  • Zam'mbuyo:
  • Ena:

  • Lembani uthenga wanu apa ndikutumiza kwa ife