Tsamba la mbendera

KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

Kufotokozera Kwachidule:

KCO SFP+ 10G ER ndi muyezo wa 10 Gigabit Efaneti pazingwe za fiber optic, zomwe zimapangidwira kufalitsa mtunda wautali.

Imaloleza kusamutsa deta mpaka 40 km pa fiber single-mode (SMF) pamtunda wa 1550nm.

KCO SFP + 10G ER fiber optic modules, yomwe nthawi zambiri imagwiritsidwa ntchito ngati ma transceivers a SFP +, amagwiritsidwa ntchito m'zinthu zosiyanasiyana zomwe zimafunika kufalikira, monga kulumikiza nyumba pamsasa waukulu kapena mkati mwa intaneti.


Tsatanetsatane wa Zamalonda

Zolemba Zamalonda

KCO-SFP+-10G-ER

+ KCO SFP+ 10G ER ndi muyezo wa 10 Gigabit Efaneti pazingwe za fiber optic, zopangidwira kutumizira anthu mtunda wautali.

+ Imaloleza kusamutsa deta mpaka 40 km pa fiber single-mode (SMF) pamtunda wa 1550nm.

+ KCO SFP + 10G ER fiber optic modules, yomwe nthawi zambiri ikugwiritsidwa ntchito ngati ma transceivers a SFP +, amagwiritsidwa ntchito m'zinthu zosiyanasiyana zomwe zimafunika kufalikira, monga kulumikiza nyumba pamsasa waukulu kapena mkati mwa intaneti.

Zogulitsa Zamankhwala

+ Mpaka 11.1Gbps Data Links

+ Kutumiza mpaka 40km pa SMF

+ EML transmitter ndi PIN wolandila

+ Kutsekeredwa kwachitsulo, kwa EMI yotsika

+ 2-waya mawonekedwe ophatikizika a Digital Diagnostic monitoring

+ Zolemba za SFP + zotentha

+ Zambiri zimagwirizana ndi SFF 8472

+ Imagwirizana ndi SFP + MSA yokhala ndi cholumikizira cha LC

+ Mphamvu imodzi ya 3.3V

+ Case ntchito kutentha osiyanasiyana:0°C mpaka 70°C

+ Kutaya mphamvu <1.5 W

Mapulogalamu

+ 10GBASE-ER/EW & 10G Efaneti

Standard

+ Zogwirizana ndi SFF-8431

+ Zogwirizana ndi SFF 8472

+ Zogwirizana ndi RoHS.

Mtheradi Maximum Mavoti

Parameter

Chizindikiro

Min.

Lembani.

Max.

Chigawo

Kutentha Kosungirako

Ts

-40

-

85

ºC

Chinyezi Chachibale

RH

5

-

95

%

Mphamvu yamagetsi yamagetsi

Chithunzi cha VCC

-0.3

-

4

V

Kulowetsa kwa Signal Voltage

VCC-0.3

-

Vcc+0.3

V

Malamulo Oyendetsera Ntchito

Parameter

Chizindikiro

Min.

Lembani.

Max.

Chigawo

Zindikirani

Kutentha kwa Ntchito

Tmlandu

0

-

70

ºC

Popanda kutuluka kwa mpweya

Mphamvu yamagetsi yamagetsi

Chithunzi cha VCC

3.14

3.3

3.47

V

Power Supply Current

ICC

-

450

mA

Mtengo wa Data

BR

10.3125

Gbps

Kutalikirana

TD

-

40

km

Wophatikiza CHIKWANGWANI

Single mode fiber

9/125um SMF

Mawonekedwe a Optical

Parameter

Chizindikiro

Min.

Lembani.

Max.

Chigawo

Zindikirani

Wotumiza

Avereji Yoyambitsa Mphamvu

PO

-1

+3

dBm

Chidziwitso (1)

Chiwerengero cha Kutha

ER

6

dB

Center Wavelength

λc ndi

1530

1550

1565

nm

Spectrum Band Width (RMS)

σ

1.0

nm

SMSR

30

dB

Transmitter OFF linanena bungwe Mphamvu

POff

-30

dBm

Chilango cha Transmitter ndi Dispersion

TDP

3.0

dB

Kutulutsa kwa Eye Mask

Zogwirizana ndi IEEE 802.3ae

Wolandira

Lowetsani Optical Wavelength

λ

1270

1610

nm

Kumverera kwa Receiver

Psen

-15.8

dBm

Chidziwitso (2)

Mphamvu Yowonjezera Machulukidwe (Zowonjezera)

Psat

0.5

dBm

LOS Detect -Kutsimikizira Mphamvu

PA

-28

dBm

LOS Detect - Mphamvu ya Dessert

PD

-19

dBm

LOS Kuzindikira Hysteresis

PHYS

0.5

dB

Zindikirani:
1. Mphamvu yoyambitsidwa (avg.) ndi mphamvu yolumikizidwa munjira imodzi yokhala ndi cholumikizira cha master. (Before of Life)
2.Kuyezedwa ndi chizindikiro choyeserera cha BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Makhalidwe Amagetsi

Parameter

Chizindikiro

Min

Lembani

Max

Chigawo

ZINDIKIRANI

Supply Voltage

Vcc

3.14

3.3

3.46

V

Supply Current

Icc

450

mA

Wotumiza

Lowetsani kusiyana kwa impedance

Rin

100

Ω

1

Kusintha kwa data kamodzi komaliza

Vin, pp

180

700

mV

Kutumiza Disable Voltage

VD

VCC–1.3

Vcc

V

Kutumiza Yambitsani Voltage

VEN

Vee

Mtengo + 0.8

V

2

Tumizani Disable Assert Time

10

us

Wolandira

Kusintha kwamitundu yosiyanasiyana ya data

Woti, pp

300

850

mV

3

Nthawi yokwera ya data

tr

28

ps

4

Data linanena bungwe kugwa nthawi

tf

28

ps

4

Zolakwa za LOS

Vuto la VLOS

VCC–1.3

VccHOST

V

5

LOS Normal

VLOS chizolowezi

Vee

Mtengo +0.8

V

5

Kukana Kwamagetsi

Zithunzi za PSR

100

mvpp

6

Zolemba:

  1. Zolumikizidwa mwachindunji ndi zikhomo za data za TX. AC yophatikizidwa pambuyo pake.
  2. Kapena kutsegula dera.
  3. Mu 100 ohms kusiyanitsidwa kosiyana.
  4. 20-80%.
  5. Kutayika Kwa Signal ndi LVTTL. Logic 0 imasonyeza ntchito yachibadwa; logic 1 ikuwonetsa kuti palibe chizindikiro chomwe chapezeka.

Kumverera kwa cholandilira kumagwirizana ndi kusinthika kwamagetsi kwa sinusoidal kwa 20 Hz mpaka 1.5 MHz mpaka pamtengo womwe waperekedwa kudzera pa netiweki yovomerezeka yosefera magetsi.

Kufotokozera Pin

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (1)

Pin

Chizindikiro

Dzina/Mafotokozedwe

ZINDIKIRANI

1

VEET

Transmitter Ground (Yodziwika ndi Ground Receiver)

1

2

TZOCHITA

Kulakwitsa kwa Transmitter.

2

3

TDIS

Transmitter Disable. Kutulutsa kwa laser kumayimitsidwa pamwamba kapena kutseguka.

3

4

SDA

2-waya Serial Interface Data Line

4

5

Mtengo wa magawo SCL

2-waya Serial Interface Clock Line

4

6

MOD_ABS

Palibe module. Kukhazikika mu module

4

7

RS0

Rate Select 0

5

8

LOS

Kutayika kwa Chizindikiro. Logic 0 ikuwonetsa ntchito yabwinobwino.

6

9

RS1

Palibe kulumikizana kofunikira

1

10

VEER

Receiver Ground (Wamba ndi Transmitter Ground)

1

11

VEER

Receiver Ground (Wamba ndi Transmitter Ground)

1

12

RD-

Wolandila Adalowa DATA kunja. AC kuphatikiza

13

RD+

Receiver DATA yosatembenuzidwa yatha. AC kuphatikiza

14

VEER

Receiver Ground (Wamba ndi Transmitter Ground)

1

15

VMtengo CCR

Receiver Power Supply

16

VMtengo CCT

Ma Transmitter Power Supply

17

VEET

Transmitter Ground (Yodziwika ndi Ground Receiver)

1

18

TD+

Transmitter Non-Inverted DATA in. AC Coupled.

19

TD-

Transmitter Inverted DATA in. AC Coupled.

20

VEET

Transmitter Ground (Yodziwika ndi Ground Receiver)

1

Zolemba:

  1. Malo ozungulira amakhala otalikirana ndi chassis.
  2. TZOCHITAndizotulutsa zotseguka / zotulutsa, zomwe ziyenera kukokedwa ndi 4.7k - 10k Ohms resistor pa bolodi lokhalamo ngati likugwiritsidwa ntchito. Kutulutsa mphamvu kuyenera kukhala pakati pa 2.0V mpaka Vcc + 0.3VA kutulutsa kwakukulu kumawonetsa vuto la transmitter lomwe limayambitsidwa ndi TX bias panopa kapena mphamvu ya TX yotuluka kupitilira ma alarm omwe adakhazikitsidwa kale. Kutulutsa kochepa kumasonyeza ntchito yabwino. Pamalo otsika, zotulutsa zimakokedwa ku <0.8V.
  3. Kutulutsa kwa laser kwayimitsidwa pa TDIS> 2.0V kapena kutsegulidwa, kuyatsa pa TDIS<0.8V.
  4. Iyenera kukokedwa ndi 4.7kΩ- ​​10kΩ host board kuti ikhale pakati pa 2.0V ndi 3.6V. MOD_ABS imakoka mzere pansi kusonyeza kuti module yalumikizidwa.
  5. Mkati adatsitsidwa pansi pa SFF-8431 Rev 4.1.
  6. LOS ndi zotuluka zotseguka. Iyenera kukokedwa ndi 4.7kΩ - 10kΩ pa bolodi yolandira alendo kuti ikhale pakati pa 2.0V ndi 3.6V. Logic 0 imasonyeza ntchito yachibadwa; logic 1 ikuwonetsa kutayika kwa chizindikiro.

Digital Diagnostic Ntchito

Ma transceivers a OP-SFP + -ER amathandizira 2-waya serial communication protocol monga tafotokozera mu SFP + MSA.

ID yokhazikika ya SFP imapereka mwayi wodziwa zambiri zomwe zimafotokozera kuthekera kwa transceiver, ma interfaces wamba, wopanga, ndi zina zambiri.

Kuonjezera apo, ma transceivers a SFP + amapereka mawonekedwe apadera opititsa patsogolo kufufuza kwa digito, omwe amalola kuti azitha kupeza nthawi yeniyeni yogwiritsira ntchito zipangizo monga kutentha kwa transceiver, laser bias current, transmitted optical power, kulandira mphamvu ya kuwala ndi transceiver supply voltage. Imatanthawuzanso kachitidwe kake ka ma alarm ndi mbendera zochenjeza, zomwe zimachenjeza ogwiritsa ntchito ngati magawo ena ogwiritsira ntchito ali kunja kwa fakitale yokhazikika.

SFP MSA imatanthawuza mapu a kukumbukira 256-byte mu EEPROM yomwe imapezeka pa 2-waya serial interface pa 8 bit adilesi 1010000X (A0h) .Mawonekedwe owunika a digito amagwiritsa ntchito adilesi ya 8 bit 1010001X (A2h), kotero mapu omwe adatchulidwa poyamba amakhalabe osasinthika a ID kukumbukira.

Zambiri zogwirira ntchito ndi zowunikira zimayang'aniridwa ndikufotokozedwa ndi Digital Diagnostics Transceiver Controller (DDTC) mkati mwa transceiver, yomwe imapezeka kudzera mu mawonekedwe a 2-waya serial. Pamene protocol ya serial itsegulidwa, chizindikiro cha wotchi (SCL, Mod Def 1) chimapangidwa ndi wolandirayo. Mawotchi abwino amawotchera deta mu transceiver ya SFP m'magawo a E2PROM omwe sali otetezedwa. M'mphepete mwa mawotchi olakwika kuchokera ku transceiver ya SFP. Chizindikiro cha serial data (SDA, Mod Def 2) ndi njira ziwiri zotsatsira deta. Wolandirayo amagwiritsa ntchito SDA molumikizana ndi SCL kuti alembe chiyambi ndi kutha kwa serial protocol activation. Zokumbukira zimakonzedwa ngati mawu amtundu wa 8-bit omwe amatha kuyankhidwa payekhapayekha kapena motsatizana.

Interface Circuit yovomerezeka

KCO-SFP+ -10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (2)

Miyeso Yaumboni

KCO-SFP+ -10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (3)

Kutsata Malamulo

Mbali

Buku

Kachitidwe

Electrostatic discharge (ESD)

IEC/EN 61000-4-2

Yogwirizana ndi miyezo

Electromagnetic Interference (EMI)

FCC Gawo 15 Kalasi B EN 55022 Kalasi B (CISPR 22A)

Yogwirizana ndi miyezo

Chitetezo cha Maso a Laser

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Class 1 laser mankhwala

ROHS

2002/95/EC

Yogwirizana ndi miyezo

Mtengo wa EMC

EN61000-3

Yogwirizana ndi miyezo

Zowonjezera A. Document Revision

Version No.

Tsiku

Kufotokozera

1.0

2010-09-01

Tsamba loyamba

2.0

2011-09-10

Sinthani mawonekedwe ndi logo ya kampani

3.0

2012-08-03

Sinthani mphamvu -1~4 mpaka -1~3


  • Zam'mbuyo:
  • Ena:

  • Lembani uthenga wanu apa ndikutumiza kwa ife