KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimode 100m MTP MPO Fiber Optic Transceiver
Kufotokozera
+ KCO QSFP56 200G SR4 S Fiber Optic Module imathandizira maulalo a 200GE ndi maulalo mpaka awiri a 100GBASE-SR2 kapena maulalo anayi a 50GBASE-SR mpaka 100m kuposa OM4 MMF.
+ Module ili ndi mawiri anayi a Multi-Mode Fiber yokhala ndi cholumikizira cha MPO-12 UPC.
+ Imagwirizana ndi IEEE 802.3bm protocol ndi 200GAUI-4/CEI-56G-VSR-PAM4 miyezo.
+ Chizindikiro cha 200 Gigabit Ethernet chimanyamulidwa pamagulu anayi ofanana a ulusi pamlingo wodziwika bwino wa 850nm pa 50Gbps pa fiber. Itha kugwiritsidwanso ntchito ngati 2x100GE breakout to 100GBASE-SR2modules. FEC imachitika papulatifomu yolandila.
+ The KCO QSFP56 200G SR4 S fiber optic transceivers ndizochita bwino, zotsika mtengo za I/O zothetsera LAN, HPC ndi SAN.
+ Ma transceivers othamanga kwambiri amakumana ndi kupitirira 200G Ethernet, InfiniBand HDR ndi zofunikira za kutentha kwa ntchito ndi kudalirika.
+ Ma transceivers amagwirizana ndi SFF-8636 ndipo amapereka kulumikizana pakati pa zida zogwiritsa ntchito madoko a QSFP56.
Kugwiritsa ntchito
+ 200GBASE-SR4 Efaneti
+ 200G InfiniBand HDR machitidwe
+ Maulalo ena owoneka
Receiver Optical Makhalidwe
| Parameter | Chizindikiro | Min | Lembani | Max | Chigawo | Zolemba |
| Pang'ono Rate | BR | - | 26.5625± 100 ppm | - | GBd | PAM4 |
| Pakati Wavelength Range | λc ndi | 840 | 850 | 860 | nm | |
| Kuwonongeka kolowera | DT | 5 | - | - | dBm | |
| Avereji amalandila mphamvu, kanjira kalikonse | PIN | -8.4 | - | 4 | dBm | |
| Landirani mphamvu, njira iliyonse (OMAouter) | PINOMA | - | - | 3 | dBm | |
| Landirani Kumverera (OMAouter), njira iliyonse | Sen | max(-6.5,SECQ-7.9) | dBm | 1, 2 | ||
| Stressed receiver sensitivity (OMAouter), njira iliyonse | SenSTR | - | - | -3.4 | dBm | 1 |
| Receiver chiwonetsero | RF | - | - | -12 | dB | |
Zindikiranis:
- BER=2.4E-4, PRBS31Q@26.5625Gbd PAM4
- Kumverera kwa receiver ndi chidziwitso ndipo kumatanthauzidwa ngati ma transmitter okhala ndi mtengo wa SECQ.
Makhalidwe Amagetsi
| Parameter | Chizindikiro | Min | Lembani | Max | Chigawo | Zolemba |
| Module Supply Current | Icc | - | - | 1364 | mA | - |
| Kutaya Mphamvu | PD | - | - | 4.5 | W | - |
| Wotumiza | ||||||
| Ma signature data(njira iliyonse) | - | 26.5625± 100 ppm | - | GBd | PAM4 | |
| Lowetsani Differential Impedance | Zin | 90 | 100 | 110 | Ω | - |
| Differential Data Input Swing | VKU, PP, | 300 | - | 900 | mvpp | - |
| Kuthetsa kusamvana kosiyana | - | - | - | 10 | % | - |
| Mtundu umodzi wokhazikika wa voliyumu | - | -0.4 | - | 3.3 | V | - |
| DC common mode voltage | - | -350 | - | 2850 | mV | - |
| Wolandira | ||||||
| Mtengo wa ma sign (njira iliyonse) | 26.5625 ± 100 ppm | mvpp | PAM4 | |||
| Kutulutsa Kusiyanasiyana kwa Impedans | Zout | 90 | 100 | 110 | Ω | - |
| Differential Data linanena bungwe Swing | VPA, PP | 300 | - | 900 | mvpp | - |
| Kusiyanasiyana kwa kuthetseratu kusagwirizana | - | - | - | 10 | % | - |
| Nthawi Yokwera Kwambiri, Nthawi Yogwa | Tr/Tf | 9.5 | - | - | ps | - |
| DC common mode voltage | - | -350 | - | 2850 | mV | - |
| Zolakwika Bit Rate | BER | - | - | 2.4E-4 | 1 | |
Ndemanga:
- PRBS31Q@26.5625Gbd PAM4