KCO-Fiver-MTP-MPO-QSFP-Banner-page-1

Chingwe cha MM OM5 12fo MPO To LC, 12fibers MTP to LC 0.3m Fan-out Patch

Kufotokozera Kwachidule:

- Cholumikizira A:

MPO-12

MTP-12

- Cholumikizira B: 12 ​​* LC Multimode (Mtundu wa beige mtundu wina ndi wosankha)

- Mtundu wa ulusi: (ma code 12 amitundu)

Ma Multimode OM5 50/125

- Polarity:

Mtundu B (wakale pantchito)

Zina zomwe mungasankhe: Mtundu A, Mtundu C

- Chingwe OD: 0.9mm

- Mtundu wa chingwe: Chubu chomasuka

- Utali wa Fanout: 0.3m (30cm)

- IL: Kutayika Kotsika Kwambiri (0.35dB)

- RL: 35dB

- Kugwiritsa ntchito: Paketi ya chigamba chapamwamba kwambiri

 

 


Tsatanetsatane wa Zamalonda

Ma tag a Zamalonda

Chingwe cha MM OM5 12fo MPO To LC, 12fibers MTP to LC 0.3m Fan-out Patch

+ Zingwe zolumikizira ma fan-out a MPO kupita ku LC kapena MTP kupita ku LC zimalumikiza ma switch a network a MPO/MTP kapena ma transceivers a high-density multi-fiber mwachindunji ku ma LC-ports otsika komanso osasunthika.

+ Imaphatikiza malo ndikuwongolera kusamutsa deta pakati pa malo pogawa mzere umodzi wa bandwidth wapamwamba kukhala maulumikizidwe osavuta kugwiritsa ntchito.

+ Chiwerengero cha Ulusi: 12fo

+ Mtundu wa Ulusi: Multimode OM5 50/125

+ Mtundu wa cholumikizira:

MPO Male

MTP Male

MPO Wachikazi

MTP Wachikazi

+ Mtundu wa Polarity:

Mtundu-A (Wolunjika)

Mtundu-B (Kugudubuza)

Mtundu C (Mtanda Wopatukana)

+ Mbali yolumikizira A:

MPO-12

MTP-12

+ Kukula kwa cholumikizira B:

LC multimode

SC multimode

ST multimode

FC multimode

Ma multimode a E2000

+ Mtundu wa chingwe: 0.9mm, LSZH, chubu chomasuka

+ Kutalika kwa chingwe: 30cm (0.3M)

Ulusi wa Multimode: OM3 vs OM4 vs OM5

+ OM5 fiber, kapena Wideband Multimode Fiber (WBMMF), ndi chingwe chowunikira chapamwamba, chobiriwira ngati laimu chomwe chapangidwira malo osungira deta othamanga kwambiri.

+ Imathandizira ma wavelength angapo (850nm mpaka 953nm) kuti ipereke 40G, 100G, ndi 400G Ethernet pa ulusi umodzi, zomwe zimachepetsa kwambiri kuuma kwa chingwe ndi ndalama zake.

+ OM5 makamaka imapangidwa kuti igwiritsidwe ntchito pa ma network amakampani ndi malo osungira deta amtambo omwe amafunika kuphatikiza kuchuluka kwa fiber.

+ Chivundikiro chapakati/chophimba: 50/125um, chofanana ndi OM3 ndi OM4.

+ Wavelength Division Multiplexing (SWDM): Ulusi woyamba wa multimode wopangidwa kuti ugwiritse ntchito SWDM, womwe umaulola kunyamula ma wavelengths osachepera anayi osiyana pa ulusi umodzi.

+ Kusiyana kwakukulu pakati pa ulusi wa OM3, OM4, ndi OM5 multi-mode ndi mphamvu yawo ya bandwidth, mtunda wapamwamba kwambiri wotumizira, ndi chithandizo cha multiplexing pa ma network afupiafupi.

+ Kuyerekeza Kofunika

- Ulusi wa OM3: Wokonzedwa bwino kuti ugwire ntchito pa 10Gbps mpaka 40Gbps pa mtunda waufupi womangira.

- Ulusi wa OM4: Mtundu watsopano wa OM3 wokhala ndi bandwidth yayikulu yolumikizira maulalo atali a 40G/100G.

- Ulusi wa OM5: Wopangidwa makamaka kuti ugwiritsidwe ntchito pogawa mafunde afupi (SWDM) kuti achepetse kuchuluka kwa mawaya onse.

+ Kugwira Ntchito Kwaukadaulo:

Mbali OM3-300 OM4 OM5
Mtundu wa Jekete Madzi Madzi / Violet Laimu Wobiriwira
M'mimba mwake wapakati 50 μm 50 μm 50 μm
Kuphimba Pakati 125 μm 125 μm 125 μm
Mafunde Othandizidwa 850 nm 850 nm 850 nm mpaka 953 nm
Mtunda Waukulu wa Ethernet wa 10G Mamita 300 Mamita 550 Mamita 550
Mtunda Waukulu wa 40G / 100G Mamita 100 Mamita 150 Mamita 150
Thandizo la SWDM No No Inde (njira 4)

 

Mapulogalamu

+ Malo osungira deta

+ Malo osungira deta a AI

+ Malo olumikizirana ndi ulalo wa nyenyezi

+ Metro, Bank, ...

+ Kulumikizana Molunjika kwa Chipangizo Kuti Chisinthe

+ Kutumiza Njira Kuchokera Kumsana Kupita Ku Chipangizo

+ Kukonza Zinthu Mochulukira

Mafotokozedwe

Mtundu

Njira Imodzi

Njira Imodzi

Ma Mode Ambiri

(APC Polish)

(UPC Polish)

(PC Polish)

Chiwerengero cha Ulusi

8, 12, 24 ndi zina zotero.

8, 12, 24 ndi zina zotero.

8, 12, 24 ndi zina zotero.

Mtundu wa Ulusi

G652D, G657A1 ndi zina zotero.

G652D, G657A1 ndi zina zotero.

OM1, OM2, OM3, OM4, ndi zina zotero.

Kutayika Kwambiri kwa Kuyika

Olemekezeka

Muyezo

Olemekezeka

Muyezo

Olemekezeka

Muyezo

Kutayika Kochepa

Kutayika Kochepa

Kutayika Kochepa

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.60dB

Kutayika Kobwerera

≥60 dB

≥60 dB

NA

Kulimba

≥ nthawi 500

≥ nthawi 500

≥ nthawi 500

Kutentha kwa Ntchito

-40℃~+80℃

-40℃~+80℃

-40℃~+80℃

Utali wa Mafunde Oyesera

1310nm

1310nm

1310nm

Mayeso olowetsa ndi kukoka

Nthawi 1000 <0.5 dB

Kusinthana

0.5 dB

Mphamvu yoletsa kupsinjika

15kgf

MPO-LC-12-Ulusi
MPO-LC-12-Ulusi

  • Yapitayi:
  • Ena:

  • Lembani uthenga wanu apa ndipo mutitumizireni