Gulu la High Density 96fo MPO Fiber Optic Patch Panel yokhala ndi ma module anayi
Kufotokozera
+ Chimango chogawa ma optical mounted optical distribution (ODF) KCO-MPO-1U-01 ndi chipangizo chomwe chimathera pakati pa zingwe zowunikira ndi zida zolumikizirana ndi kuwala, chomwe chimagwira ntchito yolumikiza, kuletsa, kusunga ndi kukonza zingwe zowunikira.
+ Chigamba chapadera ichi ndi bokosi la waya la MPO lomwe silinathe kuchotsedwa, mainchesi 19, kutalika kwa 1U.
+ Ndi kapangidwe kapadera ka malo osungira deta komwe gulu lililonse la patch lingathe kukhazikitsa mpaka ma cores 96 a LC.
+ Ingagwiritsidwe ntchito m'mapulogalamu olumikizirana mawaya ambiri monga malo osungira makompyuta, zipinda zamakompyuta, ndi malo osungira deta.
+ Chivundikiro chakutsogolo ndi chakumbuyo chochotseka, chowongolera chachiwiri chokokera, bezel yakutsogolo yochotsedwa, bokosi la ABS lopepuka la module ndi ntchito zina zaukadaulo zimapangitsa kuti zikhale zosavuta kugwiritsa ntchito pazithunzi zokhala ndi anthu ambiri kaya zili mu chingwe kapena chingwe.
+ Chigamba ichi chili ndi mathireyi onse a E-layer, chilichonse chili ndi ma rail owongolera a aluminiyamu odziyimira pawokha.
+ Mabokosi anayi a MPO module amaikidwa pa thireyi iliyonse, ndipo bokosi lililonse la module limayikidwa ndi adaputala 12 ya DLC ndi ma cores 24.
Pempho laukadaulo
| Deta Yaukadaulo | Deta | |
| P/N | KCO-MPO-1U-01-96 | |
| Zinthu Zofunika | Tepi yachitsulo | |
| Gawo la MPO | Zilipo | |
| Zinthu za gawo | Pulasitiki | |
| Doko la gawo | Doko la LC Duplex: 12 | |
| Doko la MPO: 2 | ||
| Njira yokhazikitsira gawo | Mtundu Womangidwa | |
| Mtundu wa ulusi | Njira Yoyimba (SM) 9/125 | MM (OM3, OM4, OM5) |
| Kuchuluka kwa ulusi | 8fo/ 12fo / 16fo/ 24fo | |
| Kutayika kwa kuyika | LC ≤ 0.5dB | LC ≤ 0.35dB |
| MPO ≤ 0.75dB | MPO ≤ 0.35dB | |
| Kutayika kobwerera | LC ≥ 55dB | LC ≥ 25dB |
| MPO ≥ 55dB | MPO ≥ 25dB | |
| Zachilengedwe | Kutentha kogwira ntchito: -5°C ~ +40°C | |
| Kutentha kosungirako: -25°C ~ +55°C | ||
| Chinyezi chocheperako | ≤95% (pa +40°C) | |
| Kupanikizika kwa mpweya | 76-106kpa | |
| Kulimba kwa kuyika | ≥ nthawi 1000 | |
Gawo la MPO
Zambiri zokhudza kuyitanitsa
| P/N | Nambala ya gawo. | Mtundu wa Ulusi | Mtundu wa Module | Cholumikizira 1 | Cholumikizira 2 |
| KCO-MPO-1U-01 | 1 2 3 4 | SM OM3-150 OM3-300 OM4 OM5 | 12fo 12fo*2 24fo | MPO/APC MPO SM MPO OM3 MPO OM4 | LC/UPC LC/APC LC MM LC OM3 LC OM4 |
| KCO-MPO-2U-01 | 1 2 3 4 5 6 7 8 | SM OM3-150 OM3-300 OM4 OM5 | 12fo 12fo*2 24fo | MPO/APC MPO SM MPO OM3 MPO OM4 | LC/UPC LC/APC LC MM LC OM3 LC OM4 |