1 * 16 1 × 16 1:16 LGX bokosi la mtundu wa PLC fiber optical splitter
Mafotokozedwe Akatundu:
•Chigawo cha PLC chimapangidwa pogwiritsa ntchito ukadaulo wa Planar Waveguide. Chimapereka njira yotsika mtengo komanso yosungira malo yolumikizirana. Ndi zigawo zofunika kwambiri mu ma network a FTTx ndipo ali ndi udindo wogawa chizindikiro kuchokera ku ofesi yayikulu kupita ku malonjezo ambiri. Ali ndi mafunde ambiri ogwirira ntchito kuyambira 1260nm mpaka 1620nm.
•Ndi kukula kwake kochepa, ma splitter awa angagwiritsidwe ntchito m'mapedesi apansi ndi amlengalenga komanso m'makina oyikamo ma rack. Amagwiritsidwa ntchito m'malo ang'onoang'ono, amatha kuyikidwa mosavuta m'mabokosi olumikizirana ndipo amatsekedwa mosavuta, kuti athe kuwotcherera mosavuta, ndipo safunikira kupangidwira malo osungidwa.
Banja lathu la PLC splitter lili ndi riboni kapena ulusi wotulutsa, Timapereka zinthu zonse za 1xN ndi 2xN splitter zomwe zimapangidwa kuti zigwirizane ndi ntchito zinazake.
•Ma splitter onse amapereka magwiridwe antchito owoneka bwino komanso kudalirika kwakukulu komwe kumakwaniritsa zofunikira za GR-1209-CORE ndi GR-1221-CORE.
•LGX Box type PLC fiber optical Splitter imapereka chinthu chotsika mtengo komanso chosunga malo choyenera zosowa za netiweki zomwe zimasintha nthawi zonse. Ndi kukula kwake kochepa, ma splitter awa angagwiritsidwe ntchito m'mapedesi apansi ndi amlengalenga komanso m'makina oyikamo ma rack. Kukhazikitsa ndikosavuta pogwiritsa ntchito mitundu yosiyanasiyana ya zolumikizira kapena fusion splicing.
Ntchito:
+ Ulusi ku Point (FTTX).
+ Ulusi Wopita Kunyumba (FTTH).
+ Ma Network Opanda Kuwala (PON).
+ Ma Gigabit Passive Optical Networks (GPON).
- Ma Network a M'deralo (LAN).
- Televizioni ya Cable (CATV).
- Zipangizo Zoyesera.
Mbali:
•Kutayika kochepa kwa kuyika.
•Kutayika Kochepa Kodalira Polarization.
•Kukhazikika Kwabwino Kwambiri kwa Zachilengedwe.
•Kukhazikika Kwabwino Kwambiri kwa Makina.
•Telcordia GR-1221 ndi GR-1209.
Mafotokozedwe
| Utali wa ulusi | 1mZosinthidwa | |||||
| Mtundu wa cholumikizira | SC, LC, FC kapena Zosinthidwa | |||||
| Mtundu wa CHIKWANGWANI CHA KUWONETSERA | G657AG652D Zosinthidwa | |||||
| Malangizo (dB) Osachepera * | 55 | |||||
| Kutayika Kobwerera (dB) Min * | 55 (50) | |||||
| Kugwira Ntchito ndi Mphamvu (mW) | 300 | |||||
| Kutalika kwa Mafunde Ogwira Ntchito (nm) | 1260 ~ 1650 | |||||
| Kutentha kwa Ntchito (°C) | -40~ +85 | |||||
| Kutentha Kosungirako (°C) | -40 ~ +85 | |||||
| Kukhazikitsa kwa Doko | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 |
| Kutayika kwa Kuyika (dB) Kwachizolowezi | 3.6 | 7.1 | 10.2 | 13.5 | 16.5 | 20.5 |
| Kutayika Kwambiri (dB) Max | 4.0 | 7.3 | 10.5 | 13.7 | 16.9 | 21.0 |
| Kutayika Kofanana (dB) | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.0 |
| PDL(dB) | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.35 |
| Kutayika Kodalira kwa Mafunde (dB) | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 |
| Kutayika Kodalira Kutentha (-40~85) (dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
| Kukhazikitsa kwa Doko | 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 |
| Kutayika kwa Kuyika (dB) Kwachizolowezi | 3.8 | 7.4 | 10.8 | 14.2 | 17.0 | 21.0 |
| Kutayika Kwambiri (dB) Max | 4.2 | 7.8 | 11.2 | 14.6 | 17.5 | 21.5 |
| Kutayika Kofanana (dB) | 1.0 | 1.4 | 1.5 | 2.0 | 2.5 | 2.5 |
| PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.5 |
| Kutayika Kodalira kwa Mafunde (dB) | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 1.0 |
| Kutayika Kodalira Kutentha (-40~+85°C) | 0.5 | 0.5 | 0.5 | 0.8 | 0.8 | 1.0 |
Kukula kwa bokosi la LGX:
1x2: 120x100x25mm
1x4: 120x100x25mm
1x8: 120x100x25mm
1x16: 120x100x50mm
1x32: 120x100x100mm
1x64: : 120x100x205mm
Ntchito: