1*32 1×21 1:32 ABS box type PLC splitter
Mafotokozedwe Akatundu:
•Ma splitter a PLC amachokera ku Planar Waveguide Technology. Amapereka njira yotsika mtengo komanso yosungira malo yolumikizirana. Ndi zigawo zofunika kwambiri mu ma network a FTTx ndipo ali ndi udindo wogawa chizindikiro kuchokera ku ofesi yayikulu kupita ku malonjezo ambiri. Ali ndi mafunde ambiri ogwirira ntchito kuyambira 1260nm mpaka 1620nm. Ndi kukula kwake kochepa, ma splitter awa angagwiritsidwe ntchito m'magawo apansi ndi amlengalenga komanso makina oyikamo ma rack. Amagwiritsidwa ntchito m'malo ang'onoang'ono, amatha kuyikidwa mosavuta m'mabokosi ovomerezeka olumikizirana ndipo amatsekedwa, kuti athe kuwotcherera, safunikira kupangidwira malo osungidwa. Banja lathu la PLC splitter lili ndi riboni kapena ulusi wotulutsa, Timapereka zinthu zonse za 1xN ndi 2xN splitter zomwe zimapangidwa kuti zigwiritsidwe ntchito zinazake. Ma splitter onse amapereka magwiridwe antchito otsimikizika komanso kudalirika kwakukulu komwe kumakwaniritsa zofunikira za GR-1209-CORE ndi GR-1221-CORE.
•Chopatulira cha fiber optic cha mtundu wa Pigtailed ABS module PLC chimagwiritsidwa ntchito kwambiri mu ma network a PON. Chimapereka chitetezo chokwanira cha zigawo zamkati ndi chingwe, komanso chimapangidwa kuti chikhale chosavuta komanso chodalirika, koma kuchuluka kwake ndi kwakukulu. Chimagwiritsidwa ntchito makamaka pazinthu zosiyanasiyana zolumikizira ndi kugawa (Outdoor Fiber Distribution Box) kapena makabati a netiweki.
Ntchito:
•Ulusi ku Point (FTTX).
•Ulusi Wopita Kunyumba (FTTH).
•Ma Network Opanda Kuwala (PON).
•Ma Gigabit Passive Optical Networks (GPON).
•Ma Network a Malo Apafupi (LAN).
•Televizioni ya Cable (CATV).
•Zipangizo Zoyesera.
Mbali:
•Kutayika kochepa kwa kuyika.
•Kutayika Kochepa Kodalira Polarization.
•Kukhazikika Kwabwino Kwambiri kwa Zachilengedwe.
•Kukhazikika Kwabwino Kwambiri kwa Makina.
•Telcordia GR-1221 ndi GR-1209.
•Miyezo yoyesera yokhwima komanso njira zoyesera zabwino
•Kuteteza chilengedwe (Kutsatira malamulo a ROHS)
•Chingwe cha fiber optical chigamba chingasinthidwe malinga ndi zofunikira za makasitomala (Cholumikizira Chosinthidwa/ Kutalika/ phukusi...)
Mafotokozedwe
| Utali wa ulusi | 1m Zosinthidwa | |||||
| Mtundu wa cholumikizira | SC, LC, FC kapena Zosinthidwa | |||||
| Mtundu wa CHIKWANGWANI CHA KUWONETSERA | G657A G652D Zosinthidwa | |||||
| Malangizo (dB) Osachepera * | 55 | |||||
| Kutayika Kobwerera (dB) Min * | 55 (50) | |||||
| Kugwira Ntchito ndi Mphamvu (mW) | 300 | |||||
| Kutalika kwa Mafunde Ogwira Ntchito (nm) | 1260 ~ 1650 | |||||
| Kutentha kwa Ntchito (°C) | -40~ +85 | |||||
| Kutentha Kosungirako (°C) | -40 ~ +85 | |||||
| Kukhazikitsa kwa Doko | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 |
| Kutayika kwa Kuyika (dB) Kwachizolowezi | 3.6 | 7.1 | 10.2 | 13.5 | 16.5 | 20.5 |
| Kutayika Kwambiri (dB) Max | 4.0 | 7.3 | 10.5 | 13.7 | 16.9 | 21.0 |
| Kutayika Kofanana (dB) | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.0 |
| PDL(dB) | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.35 |
| Kutayika Kodalira kwa Mafunde (dB) | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 |
| Kutayika Kodalira Kutentha (-40~85) (dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
| Kukhazikitsa kwa Doko | 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 |
| Kutayika kwa Kuyika (dB) Kwachizolowezi | 3.8 | 7.4 | 10.8 | 14.2 | 17.0 | 21.0 |
| Kutayika Kwambiri (dB) Max | 4.2 | 7.8 | 11.2 | 14.6 | 17.5 | 21.5 |
| Kutayika Kofanana (dB) | 1.0 | 1.4 | 1.5 | 2.0 | 2.5 | 2.5 |
| PDL (dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.5 |
| Kutayika Kodalira kwa Mafunde (dB) | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 1.0 |
| Kutayika Kodalira Kutentha (-40~+85°C) | 0.5 | 0.5 | 0.5 | 0.8 | 0.8 | 1.0 |
Kukula kwa gawo la ABS:
Kukula kwa 1x32: 140x115x18mm